Custom Overhead Insulated Cable Manufacturer — ACSR, AAAC, الجميح للسيارات & ABC Aerial Bundled Cable
اللجنة الانتخابية المستقلة 60502 & بكالوريوس 7870 certified overhead cables for low-voltage distribution networks — supporting AAAC, ACSR, الجميح للسيارات, and ABC bundled options tailored to project specifications.
Overhead Insulated Cable — Conductor Series for LV Aerial Distribution
Engineered for 1kV distribution networks in accordance with IEC 60502 — covering steel-reinforced, aluminum alloy, pure aluminum, and aerial bundled configurations matched to your grid topology.
الكابلات العلوية العازلة LV AAAC
عرض التفاصيل
الكابلات العلوية العازلة LV AAC
عرض التفاصيل
الكابلات العلوية العازلة LV ACSR
عرض التفاصيل
الكابلات العلوية العازلة MV AAAC
عرض التفاصيل
الكابلات العلوية العازلة MV AAC
عرض التفاصيل
الكابلات العلوية العازلة MV ACSR
عرض التفاصيلTechnical Specifications — 1kV Overhead Insulated Cable Series
| نموذج | نوع الموصل | العزل | تصنيف الجهد | Available Cores | Cross-Section Range | Applicable Standard |
|---|---|---|---|---|---|---|
| الكابلات العلوية العازلة LV ACSR | ACSR (Steel-Reinforced Aluminum) | XLPE / بولي كلوريد الفينيل | 1 كيلو فولت | 1C – 4C | 25 - 400 مم² | اللجنة الانتخابية المستقلة 60502 |
| الكابلات العلوية العازلة LV AAAC | AAAC (All Aluminum Alloy) | XLPE / بولي كلوريد الفينيل | 1 كيلو فولت | 1C – 4C | 25 - 400 مم² | اللجنة الانتخابية المستقلة 60502 |
| الكابلات العلوية العازلة LV AAC | الجميح للسيارات (All Aluminum) | XLPE / بولي كلوريد الفينيل | 1 كيلو فولت | 1C – 4C | 25 - 400 مم² | اللجنة الانتخابية المستقلة 60502 |
| ABC الكابلات العلوية | الجميح للسيارات / AAAC (Bundled) | XLPE | 1 كيلو فولت | 2ج / 4ج | 16 - 400 مم² | اللجنة الانتخابية المستقلة 60502 / بكالوريوس 7870 |
Specifications reference standard production ranges. Custom cross-sections, core configurations, ألوان العزل, and drum lengths are supported on request.
Factory-Direct Custom Overhead Cable for Distribution Projects
From single-drum orders to full-project BOM supply, manufacturing capabilities cover conductor material selection, insulation compound, العد الأساسي, drum length, and marking requirements — all aligned to your local grid standard or project specification sheet. For multi-product projects, submit a full BOM and our engineering team will review conductor sizing, insulation compatibility, and standard alignment.
- Conductor selection: ACSR, AAAC, or AAC matched to mechanical load and corrosion requirements
- Insulation compound: XLPE for long-term thermal performance; PVC for cost-sensitive applications
- Cross-section & العد الأساسي: Non-standard sizes from 16 ملم² إلى 400 مم², 1C through 4C
- Drum length & reel marking: Project-specific cut lengths with custom reel labeling and sequential marking
- Standard compliance: اللجنة الانتخابية المستقلة 60502, اللجنة الانتخابية المستقلة 61089, بكالوريوس 7870, or client-specified national standard
Built on a Verified Manufacturing Foundation
الإنتاج المملوك للمصنع
Vertically integrated cable production — from conductor stranding to insulation extrusion — under one roof, with no subcontracting on core processes.
25+ سنوات من الخبرة
Over two decades supplying overhead insulated cable to utility projects, برامج كهربة الريف, and urban grid upgrades worldwide.
اللجنة الانتخابية المستقلة & متوافق مع درجة البكالوريوس
Full-range compliance with IEC 60502, اللجنة الانتخابية المستقلة 61089, و بكالوريوس 7870, supported by in-house testing and third-party certification documentation.
130+ الدول التي تم تسليمها
Active export records across Africa, جنوب شرق آسيا, الشرق الأوسط, and South America — with experience in local grid standards and documentation requirements.
Overhead Insulated Cable — Common Questions from Engineers & Procurement Teams
اي بي سي (الجوي المجمعة كابل) integrates multiple insulated conductors into a single self-supporting bundle. Unlike bare conductors, the XLPE insulation eliminates phase-to-phase and phase-to-ground contact faults caused by tree branches, wind sway, or accidental contact. Installation clearance requirements are significantly reduced, making ABC the preferred choice for urban distribution networks, forested routes, and last-mile connections where conventional bare lines would require frequent maintenance or right-of-way clearing.
Overhead insulated cable and underground (الدفن المباشر) cable are not interchangeable. Overhead cables are engineered for UV resistance, mechanical self-support, and aerial installation methods, while underground cables require armor, moisture barriers, and burial-grade jacket compounds. Using an overhead cable in a direct burial application — or vice versa — will result in premature insulation degradation and does not meet IEC installation standards. Confirm the installation environment before specifying the cable type.
The three conductor types serve distinct engineering priorities. ACSR (موصل الألمنيوم بالفولاذ المقوى) provides high tensile strength for long spans or mountainous terrain, using a steel core for mechanical support. AAAC (جميع موصلات سبائك الألومنيوم) offers comparable strength to ACSR without the steel core, making it the preferred choice for coastal and high-humidity environments where galvanic corrosion between dissimilar metals is a concern. الجميح للسيارات (جميع موصلات الألومنيوم) delivers the highest conductivity-to-weight ratio and is the most cost-effective option for short to medium spans in moderate loading conditions.
ال 1 kV rating reflects the design scope of this product category: low-voltage (LV) aerial distribution — the final distribution stage from substation secondary winding to end-user connection points. Medium-voltage (إم في) or high-voltage (الجهد العالي) aerial cables require substantially different insulation thickness, conductor construction, and testing protocols under separate IEC standards (على سبيل المثال, اللجنة الانتخابية المستقلة 60502-2 for MV). If your project involves voltages above 1 كيلو فولت, contact the engineering team to discuss the appropriate product category.
Core selection depends on the distribution system configuration. A 2-core ABC bundle is typically used for single-phase service drops or two-wire secondary distribution. A 4-core ABC bundle suits three-phase + neutral LV distribution, covering the majority of urban and rural grid extension applications. In some configurations, a separate bare concentric neutral messenger wire is included; confirm with the project engineer whether a 4-core bundle or a 3-core + messenger arrangement is specified in your local grid standard.
نعم. Standard production covers the cross-sections and core counts listed in the specification table above. For non-standard cross-sections, alternate insulation colors (for phase identification per local grid codes), sequential footage or meter marking, custom drum lengths, or OEM print on the jacket, submit the project specification sheet or marking requirements through the inquiry form. The engineering team will confirm feasibility and lead time based on the specific configuration.