Custom Overhead Insulated Cable Manufacturer — ACSR, AAAC, الجميح للسيارات & ABC Aerial Bundled Cable
اللجنة الانتخابية المستقلة 60502 & بكالوريوس 7870 certified overhead cables for low-voltage distribution networks — supporting AAAC, ACSR, الجميح للسيارات, and ABC bundled options tailored to project specifications.
Overhead Insulated Cable — Conductor Series for LV Aerial Distribution
Engineered for 1kV distribution networks in accordance with IEC 60502 — covering steel-reinforced, aluminum alloy, pure aluminum, and aerial bundled configurations matched to your grid topology.
LV AAAC Insulation Overhead Cable
عرض التفاصيل
LV AAC Insulation Overhead Cable
عرض التفاصيل
LV ACSR Insulation Overhead Cable
عرض التفاصيل
MV AAAC Insulation Overhead Cable
عرض التفاصيل
MV AAC Insulation Overhead Cable
عرض التفاصيل
MV ACSR Insulation Overhead Cable
عرض التفاصيلTechnical Specifications — 1kV Overhead Insulated Cable Series
| نموذج | Conductor Type | العزل | Voltage Rating | Available Cores | Cross-Section Range | Applicable Standard |
|---|---|---|---|---|---|---|
| LV ACSR Insulation Overhead Cable | ACSR (Steel-Reinforced Aluminum) | XLPE / بولي كلوريد الفينيل | 1 كيلو فولت | 1C – 4C | 25 - 400 مم² | اللجنة الانتخابية المستقلة 60502 |
| LV AAAC Insulation Overhead Cable | AAAC (All Aluminum Alloy) | XLPE / بولي كلوريد الفينيل | 1 كيلو فولت | 1C – 4C | 25 - 400 مم² | اللجنة الانتخابية المستقلة 60502 |
| LV AAC Insulation Overhead Cable | الجميح للسيارات (All Aluminum) | XLPE / بولي كلوريد الفينيل | 1 كيلو فولت | 1C – 4C | 25 - 400 مم² | اللجنة الانتخابية المستقلة 60502 |
| ABC Overhead Cable | الجميح للسيارات / AAAC (Bundled) | XLPE | 1 كيلو فولت | 2ج / 4ج | 16 - 400 مم² | اللجنة الانتخابية المستقلة 60502 / بكالوريوس 7870 |
Specifications reference standard production ranges. Custom cross-sections, core configurations, insulation colors, and drum lengths are supported on request.
Factory-Direct Custom Overhead Cable for Distribution Projects
From single-drum orders to full-project BOM supply, manufacturing capabilities cover conductor material selection, insulation compound, core count, drum length, and marking requirements — all aligned to your local grid standard or project specification sheet. For multi-product projects, submit a full BOM and our engineering team will review conductor sizing, insulation compatibility, and standard alignment.
- Conductor selection: ACSR, AAAC, or AAC matched to mechanical load and corrosion requirements
- Insulation compound: XLPE for long-term thermal performance; PVC for cost-sensitive applications
- Cross-section & core count: Non-standard sizes from 16 mm² to 400 مم², 1C through 4C
- Drum length & reel marking: Project-specific cut lengths with custom reel labeling and sequential marking
- Standard compliance: اللجنة الانتخابية المستقلة 60502, اللجنة الانتخابية المستقلة 61089, بكالوريوس 7870, or client-specified national standard
Built on a Verified Manufacturing Foundation
الإنتاج المملوك للمصنع
Vertically integrated cable production — from conductor stranding to insulation extrusion — under one roof, with no subcontracting on core processes.
25+ سنوات من الخبرة
Over two decades supplying overhead insulated cable to utility projects, rural electrification programs, and urban grid upgrades worldwide.
اللجنة الانتخابية المستقلة & BS Compliant
Full-range compliance with IEC 60502, اللجنة الانتخابية المستقلة 61089, and BS 7870, supported by in-house testing and third-party certification documentation.
130+ الدول التي تم تسليمها
Active export records across Africa, Southeast Asia, الشرق الأوسط, and South America — with experience in local grid standards and documentation requirements.
Overhead Insulated Cable — Common Questions from Engineers & Procurement Teams
اي بي سي (Aerial Bundled Cable) integrates multiple insulated conductors into a single self-supporting bundle. Unlike bare conductors, the XLPE insulation eliminates phase-to-phase and phase-to-ground contact faults caused by tree branches, wind sway, or accidental contact. Installation clearance requirements are significantly reduced, making ABC the preferred choice for urban distribution networks, forested routes, and last-mile connections where conventional bare lines would require frequent maintenance or right-of-way clearing.
Overhead insulated cable and underground (direct burial) cable are not interchangeable. Overhead cables are engineered for UV resistance, mechanical self-support, and aerial installation methods, while underground cables require armor, moisture barriers, and burial-grade jacket compounds. Using an overhead cable in a direct burial application — or vice versa — will result in premature insulation degradation and does not meet IEC installation standards. Confirm the installation environment before specifying the cable type.
The three conductor types serve distinct engineering priorities. ACSR (Aluminum Conductor Steel Reinforced) provides high tensile strength for long spans or mountainous terrain, using a steel core for mechanical support. AAAC (All Aluminum Alloy Conductor) offers comparable strength to ACSR without the steel core, making it the preferred choice for coastal and high-humidity environments where galvanic corrosion between dissimilar metals is a concern. الجميح للسيارات (All Aluminum Conductor) delivers the highest conductivity-to-weight ratio and is the most cost-effective option for short to medium spans in moderate loading conditions.
The 1 kV rating reflects the design scope of this product category: low-voltage (LV) aerial distribution — the final distribution stage from substation secondary winding to end-user connection points. Medium-voltage (إم في) or high-voltage (HV) aerial cables require substantially different insulation thickness, conductor construction, and testing protocols under separate IEC standards (على سبيل المثال, اللجنة الانتخابية المستقلة 60502-2 for MV). If your project involves voltages above 1 كيلو فولت, contact the engineering team to discuss the appropriate product category.
Core selection depends on the distribution system configuration. A 2-core ABC bundle is typically used for single-phase service drops or two-wire secondary distribution. A 4-core ABC bundle suits three-phase + neutral LV distribution, covering the majority of urban and rural grid extension applications. In some configurations, a separate bare concentric neutral messenger wire is included; confirm with the project engineer whether a 4-core bundle or a 3-core + messenger arrangement is specified in your local grid standard.
نعم. Standard production covers the cross-sections and core counts listed in the specification table above. For non-standard cross-sections, alternate insulation colors (for phase identification per local grid codes), sequential footage or meter marking, custom drum lengths, or OEM print on the jacket, submit the project specification sheet or marking requirements through the inquiry form. The engineering team will confirm feasibility and lead time based on the specific configuration.